Home> Blog> Determination of tin in copper-tin alloy by AA-1800 atomic absorption spectrometry

Determination of tin in copper-tin alloy by AA-1800 atomic absorption spectrometry

November 01, 2022
F380J106MMA original authentic, spot stock brand NICHICON
Electronic scale crystal oscillator 3.2*2.5mm 3225 16M (16.000MHZ) 12PF 10PPM 20PPM 30PPM
Test - lowercase jpg
Kaixin micro test

Determination of tin in copper-tin alloy by AA-1800 atomic absorption spectrometry

Key words: atomic absorption spectrometer; tin in copper-tin alloy; aesthetic analyzer ; AA1800C Abstract: The copper-tin alloy was digested by wet method, and the tin content in the alloy was detected by flame atomic absorption spectrometry. Compared with the test results of the analytical methods required in GB/T5121.10-2008, the results show that the results obtained by using the atomic absorption test and the results obtained by using the ultraviolet-visible spectrophotometer are consistent, and the operation is simple, fast and saves reagents. The copper alloy with tin as the main additive element is called copper-tin alloy, and its application range is wide, especially in deep processing. For example, it is widely used in shipbuilding, chemical, machinery, instrumentation and other industries. It is suitable for manufacturing bearings and corrosion resistance. , diamagnetic parts and springs, etc., can also manufacture parts that require wear and corrosion resistance, such as pump body, bearing bush, gear, worm gear and so on. The amount of tin directly affects the microstructure and mechanical properties of copper-tin alloys, so accurate detection of tin content in copper-tin alloys is crucial for production and processing. 1. Experimental part 1.1 Instrument and working conditions AA1800 atomic absorption spectrophotometer (MEAS China); tin hollow cathode lamp; instrument working parameters: wavelength 286.6nm, current 7mA, slit 0.2nm, burner height 10mm; 1.2 Standard solution and reagent nitric acid (excellent grade); tin standard solution; 1.3 sample processing method sample processing method: accurately weigh 3.0020g sample, placed in a 100ml polytetrafluoroethylene beaker, and added with appropriate amount of deionized water to wet The sample was added with 8 mL of nitric acid and placed on a hot plate to dissolve. After completion, it was added to a 25 ml plastic volumetric flask and made up to volume with deionized water. At the same time, the sample method is used to make the sample blank. 1.4 Working curve The instrument is calibrated by standard addition method: take 4 10mL volumetric flasks, separately transfer 1.3ml of digestive juice into 3 volumetric flasks, and add tin standard solution, so that the concentration of tin added to the standard solution is 0μg respectively. /mL, 100μg/mL, 200μg/mL, 300μg/mL; make up to the mark with ultrapure water. In addition, remove 5mL of blank solution and 10mL volumetric flask, and dilute to the mark with ultrapure water. 1.5 On-machine detection Use the blank solution to calibrate the zero point of the atomic absorption spectrometer, measure the absorbance of the sample solution, take the average of three measurements, and make a calibration curve by adding the concentration of the standard solution and the measured absorbance of the sample solution. 2. Test results From the above results, it is easy to see that the use of flame atomic absorption detection of tin content in copper-tin alloy, and GB/T5121.10-2008 specified using UV-visible spectrophotometer test results are consistent, and save Going to the tedious pretreatment and color reaction using UV-Vis spectrometer. The method uses the standard addition method to eliminate the interference of the matrix, obtains better reproducibility and detection results, and is simple, quick and saves reagents. Key words: atomic absorption spectrometer; tin in copper-tin alloy; aesthetic analyzer ; AA1800C


Copyright (c) 2013 All rights reserved: US Analysis (China) Instruments Shanghai ICP No. 13043738-1
Main:

Spectrophotometer, ultraviolet spectrophotometer, UV-visible spectrophotometer

Marketing Center: 711, Block A, Haige International Building, Xuanwumen, Xicheng District, Beijing

Contact Us

Author:

Mr. Yan

Phone/WhatsApp:

8618098231343

Popular Products
You may also like
Related Information
Metal Slitting Machine/Metal Precision Slitting Line/Metal Slitting Line

Model NO.: Metal Slitting Machine/Metal Precision Slitting Li Coil Weight: 25-35t Overseas Service: Lifetime Max Speed: 10-250m/Min Package: Naked Package and Fixed in The Container Trademark: Wuxi...

Metal Coil Metal Cut to Length Line/Metal Cut to Length

Model NO.: Metal Coil Metal Cut To Length Line/Metal Cut To L Thickness Range: 0.1-4mm Raw Material: Cr Steel, Al, PPGI, Hr, Silicon Steel Cutting Length Precision: Plus Minus 0.3-0.5 Package: Naked...

Plf Metal Connector Brass Metal Pneumatic Fitting

Model NO.: MPLF16-04 Material: Brass Connection: Push-in Model Number: Poc Straight Metle Fitting OEM: Yes Trademark: A&M Transport Package: Plastic Bag+Box+Carton Specification: normal Origin:...

Collapsible Metal Foldable Storage Metal Cage

Model NO.: F28 Wire diameter: 6.2 Company Type: China Professional Manufacturer Material: Mild Steel Product Warranty: 1 Year Interior Dimension: 1134*978*1050mm(L*W*H) Exterior Dimension:...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send